Using supplemental dehumidification to remove unwanted moisture and prevent problems associated with hot-humid climates
Download a PDF version of this Case Study by clicking HERE.
Location
South Florida
Issue Reported
Efficiency and one-bedroom apartments were experiencing elevated relative humidity (RH) for extended periods of time resulting in resident complaints, mildew and in some cases mold growth.
Type / Construction Concrete construction with stucco finish.
Background
Innovative Dehumidifier Systems was contacted by property management at this South Florida luxury apartment property to resolve various moisture related problems inside apartments. Mechanical system design included unconditioned outside air being introduced into mechanical closets. Additionally, some of the one-bedroom units were served by 2-ton split air conditioners which were grossly over-sized. Prior to the installation of the IW-25 in-wall dehumidifier, some of the two-ton air conditioners were replaced by 1.5 ton units with some improvement; however, RH remained elevated.
Process
The first IW-25 in-wall dehumidifier was installed adjacent to the living room of a one-bedroom unit. An iMonnit data logging system was placed and humidity sensors were placed inside and out to monitor temperature and relative humidity (RH).
Ambient Humidity – Outside Air Outdoor RH ranged between 70% and 95% during the monitored period Average RH was in excess of 86%RH Moisture-laden outside air was being introduced into apartments
Monitoring unit 311 – Bathroom Indoor RH prior to installation of the IW-25 ranged between 67% and 78% RH Air-conditioner run cycles were documented as short at 4.5 minutes
RH was maintained at safe and acceptable levels between 52% and 56% after the IW-25 was installed
Ambient Humidity – Outside Air
Outdoor RH ranged between 70% and 95% during the monitored period
Average RH was in excess of 86%RH
Moisture-laden outside air was being introduced into apartments
Monitoring unit 311 – Bathroom
Indoor RH prior to installation of the IW-25 ranged between 67% and 78% RH
Air-conditioner run cycles were documented as short at 4.5 minutes
RH was maintained at safe and acceptable levels between 52% and 56% after the IW-25 was installed
Monitoring unit 311 – Bathroom
Secondary sensors were placed in the bathroom to take additional temp & RH data
Data measurements were accumulated every 10 minutes
Conclusion
Prior to the installation of the IW-25 in-wall dehumidifier in the apartments, thousands of dollars were spent on ineffective corrective action including consulting engineers, replacement mechanical systems and temporary solutions such as portable dehumidifiers. Not only was the IW-25 the most effective moisture control solution for this application, it was by far the least expensive. Contact Innovative Dehumidifiers to learn more about the award-winning IW-25 and see how we can help you achieve ideal room humidity.